zurück zur Übersicht

Active Front End (AFE) - DC/DC Chopper (with galvanic isolation) - Inverter

schema drawing with elements for the power line from Temes engeneering


Facts

  • Storage temperature: -33°C … +71°C
  • Operating temperature: -32°C … +60°C
  • Degree of contamination: Level2 EN 60664-1
  • Isolation: 2.5kV AC RMS 1min, Increased for 1.5 and 3kV applications
  • Power Electronics, general Sea level altitude, operation: 2.000m, 3.000m with reduced performance
  • Maximum transport height: 16.000 feet (4.876m) without pressure compensation
  • Humidity: Humidity 3% to 100% including condensation during storage and commissioning.
  • Vibration: MIL-STD-810-H, Method 514.8 Kat. 4

Variation

Active Front End Module (AFE) and Inverter

  • High frequency 3-phase Topology with sinusoidal current draw
  • Clock frequency >30kHz
  • Built-in micro-processor control- and regulation
  • CAN Interface
  • Integrated filter and EMI filter
  • Dimension 19“ slide in unit; four height-units; Depth: 475mm
  • Weigt: 50kg
  • 3 x 400V AC (1-phasse 230V AC on request) +/- 10%; 47 … 63Hz
  • Power: 65kW / 75kW continuous/peak power
  • Power Factor: > 0,98 (AFE operation)
  • THD: < 5% (Inverter operation)
  • Efficiency: > 97.5% (AFE & Inverter operation)
  • Cooling: Liquid Cooling, max. 60°C liquid cooling temperature

DC-DC Module (galvanic Isolation)

  • High frequency full bridge topology
  • Clock frequency : >50kHz
  • Built-in micro-processor control- and regulation
  • CAN Interface
  • Integrated filter and EMI filter
  • Integrated 60kW chopper for battery charging and operation at PV (Photo Voltaic)
  • Input / output: 600 … 820 V DC, 
  • Power: 60 kW continuous/peak power
  • Efficiency: > 95%
  • Dimensions: 19“ slide in unit; four height-units; Depth: 475mm
  • Weight: 55kg
  • Cooling: Liquid Cooling, max 60°C liquid cooling temperature

Description

Each Module can be used stand alone, or up to 6 Modules each can be operated in parallel, resulting in a max. system power of > 350kW.

Each four DC-DC modules can be operated in series as an option (increased isolation strength).
This allows operation at nominal 3kV DC systems.

 


Request now

Downloads

Presentation Power Line V3

View of our building in Otterfing

Contact

Temes Engineering GmbH
Gewerbering 9
83624 Otterfing

go to google maps

info@temesonline.de

+49 8024 473880

High level engineering is not just printed on our label,

Icon Made in Germany

it is actually there.
That satisfies our customers.

Kontakt EN

Contact us & say hello

All fields with (*) are required.

I accept the privacy policy.